Electronic blaine airpermeability apparatus for determining the fineness of cement. Test method a is the reference test method using the. This international standard specifies a method to determine the fineness of iron ores in terms of specific surface area, using the manual blaine airpermeability apparatus. Hmkc2 automatic blaine apparatus is a cement testing apparatus used to determine the particle size of portland cement, limes and similar powders using the blaine air permeability method. To391 model of auto blaine apparatus from tinius olsen. Variable flow type air permeability apparatus blaine type no.
Blaine air permeability apparatus fineness specific surface. Put another filter paper on it and compress with the plunger. Includes an 8 oz blaine air permeability apparatus the blaine air permeability apparatus determines the fineness of portland cement in terms of specific surface area expressed as the total surface area in square centimeters per gram of mortar or cement. Jun 05, 2019 how to operate the manual blaine air permeability apparatus testing 1.
Specification variable flow type airpermeability apparatus blaine type number of amendments. The blaine fineness method covers the determination of the fineness of hydraulic cement, using the blaine airpermeability apparatus, in terms of the specific surface expressed as total surface area in square centimeters per gram, or square meters per kilogram, of cement. What is the fineness of cement its test and effects. Hmkc1 blaine apparatus is a cement testing apparatus used to determine the particle size of portland cement, limes and similar powders using the blaine air permeability method. It is used to establish the fineness of cement using the blaine airpermeability apparatus, in terms of definite surface expressed as total surface area in square meters per kilogram, or square centimeters per gram, of cement. Blaine air permeability apparatus pdf automatic blaine air permeability apparatus testing equipment cementmortar. To determine the fineness of cement by determining specific surface by blaines air permeability method is 4031 1958. Hmkc1 blaine apparatus is a cement testing apparatus used to determine the particle size of portland cement, limes and similar powders using the blaine airpermeability method. The apparatus constant is determinate by measuring permeability of reference cement of known. Hmkc2 automatic blaine apparatus is a cement testing apparatus used to determine the particle size of portland cement, limes and similar powders using the blaine airpermeability method. Jan 30, 2020 air permeability apparatus blaine type aimil ltd.
Oct 11, 2019 blaine air permeability apparatus, laboratory. How to operate the manual blaine air permeability apparatus. This blaine apparatus has a manual aspirator to apply the air pressure for the test. The humboldt blaine air permeability apparatus consists of. Hmkc2 automatic blaine air permeability apparatus aimsizer. How to operate the manual blaine air permeability apparatus testing 1. Apparatus specifications 1 flow type air permeability conforming to is. Apparatus measuring instruments name range accuracy blaine air permeability apparatus refer to.
Calibrate the blaine vaseline grease glass thermometer 0c to 50c qty 1no. Une 80122, en 1966, astm c204, bs 4359 fineness of cement the apparatus use to determine the specific surface of cement. Blaine air permeability apparatus fineness specific. Read about company and get contact details and address. By using this apparatus, a quantity of air is drawn through a bed of definite porosity. It gives the test results of specific surface area. Hmkc1 cement blaine airpermeability apparatus hmktest. Blaine air permeability apparatus myers cement testing. The blaine works by drawing a definite quantity of air through of bed of cement exhibiting a definitive porosity value. We offer a variety of blaine systems fitting the needs of the industry. The automatic blaine apparatus from tinius olsen is an automated version of blaine apparatus and follows global standards. Ma10 blaine air permeability apparatus for determining the fineness of portland cement measures the specific surface area of fine materials in square centimeters per gram of test sample.
Aashto t153, astm c204, bs 43592, en 1966, isiri 188076 general discriptions download manual. Designed for the determination of fineness to en 1966, bs 43592, astm c204. Ele international blaine air permeability apparatus. Fineness air permeability final 1 linkedin slideshare. Chapter 12testing of cement part 1 page 61 a bed of cement is prepared in special permeability cell and have exact porosity e 0,500 weight a quantity of cement.
Cement and concrete indian standard variable flow type airpermeability apparatus blaine type specification first revision ks 91. The utcm0240 blaine air permeability apparatus is used to determine the fineness of portland cement, limes and similar powders expressed in terms of their specific surface. It determines the fineness of portland cement, using the blaine airpermeability method. Generally blaine air permeability apparatus is used. It completely meets astm c204 standard test methods for fineness of hydraulic cement by air permeability apparatus test method a using the manually operated. Overview blaines air permeability apparatus consists essentially of a means of drawing a definite quantity of air through a prepared bed of cement of definite porosity. Blaine fineness apparatus, determination of fineness blaine apparatus. Save page to pdf the page to pdf system has been restored. Astm c204 11 standard test methods for fineness of. The digital blaine permeability autoblaine plus model is manufactured according to specifications of the following standards.
The specific surface is derived from the resistance to flow of air or some other gas through a porous bed of the powder. Blaine air permeability apparatus blaine apparatus impact civil. Blaine air permeability apparatus the blaine air permeability apparatus determines the fineness of portland cement in terms of specific surface area expressed as the total surface area in square centimeters per gram of mortar or cement. Air permeability apparatus blaine type aim 390 ref. As well as a rubber aspirator bulb and perforated disc. The calibration of the air permeability apparatus shall be made using the standard reference material. It gives accurate and repeatable test results of cement specific surface area. E009 kit blaine air permeability apparatus cementmortar aashto t153. Specification variable flow type air permeability apparatus blaine type number of amendments. The standard humboldt blaine air permeability apparatus consists of. Blaine air permeability apparatus ele international. Jan 30, 2020 blaine air permeability apparatus fineness specific surface utest material testing equipment number of employees 11 to 25 people. Hmkc1 blaine apparatus consists of a stainless steel cell, perforated disc and plunger. The fineness is expressed as a total surface area in square centimeters per gram.
The digital blaine permeability autoblaine plus model is. Fineness, determination of fineness blaine apparatus. The blaine air permeability apparatus determines fineness of portland cement. The rate of air flow is determined by the pore volume in the bed, a function of the size of particles. Blaine air permeability apparatus blaine apparatus. The unit consists of a calibrated utube manometer, ground glass joint, stainless steel test cell and plunger. Standard test methods for fineness of hydraulic cement by air. Jun 18, 2014 blaines air permeability apparatus consists essentially of a means of drawing a definite quantity of air through a prepared bed of cement of definite porosity. Legally binding document step out from the old to the newjawaharlal nehru invent a new india using knowledge.
It is used to determine the fineness of cement using the blaine airpermeability apparatus, in terms of the specific surface expressed as total surface area in square centimetres per gram, or. Blaine air permeability apparatus 6 different types. Overview blaine s air permeability apparatus consists essentially of a means of drawing a definite quantity of air through a prepared bed of cement of definite porosity. The second revision of this standard has been prepared with a view to aligning this test method with european standard en 196 part 6 method of testing cement. The blaine air permeability apparatus is used to determine the fineness of portland cement in terms of the specific surface expressed as total surface area in square centimetres per gram of cement. It determines the fineness of portland cement, using the blaine air permeability method. The automated test method shall employ apparatus designed either on the principles of the blaine air permeability method or apparatus based on the air permeability principles of the lea and nurse method. Apparatus measuring instruments name range accuracy blaine air permeability apparatus refer to is. Evacuate the air in the manometer through the side tube using the aspirator bulb until the oil reaches level 1. The blaine apparatus is used to determine the fineness of cement and other.
The air permeability specific surface of a powder material is a singleparameter measurement of the fineness of the powder. Hmkc2 blaine apparatus consists of a stainless steel cell, perforated disc and. The apparatus is supplied with a glass utube manometer with valve, steel stand, test cell with disk and plunger all in stainless steel, rubber aspirator bulb, filter paper disks, manometer liquid and accessories. Hmkc1 cement blaine fineness air permeability apparatus. This international standard is applicable to pellet feeds in the range of 400 cm 2. Astm c204 18e1 standard test methods for fineness of. The apparatus is used for determining the fineness of cement in terms of specific surface expressed as total surface area in square centimeters per gram of cement. Standard test methods for fineness of hydraulic cement by airpermeability apparatus. This apparatus is used to determine the fineness of portland cement in. Blaine air permeability apparatus blaine apparatus impact.
Utcm0246 reference cement should be ordered separately. The apparatus is supplied with a glass utube manometer with valve, steel stand, test cell with. H monometer utube, calibrated for blaine air apparatus. Abmb 02060209 manual the 02060209 manual air permeability tester is able to perform the blaine test with a traditional design. This device is a semiautomatic cement air permeability tester. Hmkc1 blaine apparatus is a cement testing equipment. It completely meets astm c204 standard test methods for fineness of hydraulic cement by airpermeability apparatus test method a using the manually operated. Test method a is the reference test method using the manually operated standard.
Description gottbapfa 01 is designed to determine the fineness of portland cement in terms of the specific surface expressed as total surface area in square centimeters per gram of cement. Pc controlled, fully automatic blaine air permeability apparatus for fully automatic testing and analysis standards en1966, astm c204, bs 4550 a pc is required for use with the automatic blaine air permeability apparatus. Auto blaine apparatus tinius olsens automatic blaine apparatus is an automated version of blaine apparatus and follows the international standards. In the instrument described below, air permeability method i. To determine the fineness of cements, pozzolanas and other powdery materials, various international specifications recommend the use of specific area method. Blaine air permeability apparatus used to determine used to determine the fineness of portland cement in terms of the specific surface expressed as total surface area in square centimeters per gram of cement. Blaine fineness apparatus, determination of fineness blaine apparatus designed for the determination of fineness to en 1966, bs 43592, astm c204 supplied complete with stainless stell cell perforated disc and plunger manometer utube aspirator bottle of manometer liquid pure mineral 1 litre and a box of filter papers.
Blaine air permeability fineness apparatus proposed design only, subject to changes without any notice. Blaine air permeability, cement fineness humboldt mfg. Tmc engineering private limited offering blaine air permeability apparatus, laboratory in chennai, tamil nadu. Hmkc2 blaine apparatus consists of a stainless steel cell, perforated disc and plunger.
121 396 582 1226 486 124 1110 122 271 159 1637 1420 936 1366 1570 63 585 453 1270 676 374 556 1588 1186 1227 450 115 629 35 996 190 1600 1517 856 476 989 396 911 105 935 1465 1311 104